Technical Paper
Real-Time Measurement of Particle Size Distribution From Diesel Engines Equipped With Continuous Regenerative DPF Under a Transient Driving Condition
2004-06-08
2004-01-1984
A new PM measurement method, such as particle measurement equipments, samplings and so on, is being studied at present for a type approval test in the future. Particles emitted from diesel engines, especially the particles that are called “Nuclei Mode Particles” are very unstable and easily influenced by the engine operating conditions and the measurement conditions. Most of nuclei mode particles are said to consist of volatile organic particles with mainly high carbon numbers. It is said that a continuous regenerative type DPF (Diesel Particulate Filter) consisting of oxidation catalyst and ceramic filter will prevail in the near future. These particles may be able to be reduced by an oxidation catalyst in this DPF.